Cathodic Protection
  Corrosion Engineering
  Construction Services
  Electrical Engineering Services
  Forensic Services
  Pipeline Induced AC
  Pipeline Integrity Management
 
  - What's New
  - Published Works
  - Case Histories
Published Works

Published Works

Papers
PDF
Retrofit Induced AC Mitigation - NACE International. All rights reserved. Reproduced with permission from CORROSION/2003 Annual Conference and Exhibition, San Diego, CA
Cathodic Protection of a Well Grounded Tank Farm and Pump Station in Colombia, S.A. - NACE International. All rights reserved. Reproduced with permission from CORROSION /2004 Annual Conference and Exhibition
Electrical Grounding Case Histories - NACE International. All rights reserved. Paper No. 03701 reproduced with permission from CORROSION/2003 Annual Conference and Exhibition, San Diego, CA
Improved Grounding Causes Minimal Impact on CP Systems - NACE International. All rights reserved. Materials Performance, January 2003
The Conflict Between Copper Grounding Systems and Cathodic Protection Systems
Conflict Between Copper Grounding and CP in Oil &Gas Production Facilities - NACE International. All rights reserved. Materials Performance, August 2002
Electrical Grounding and Cathodic Protection Issues in Large Generating Stations - NACE International. All rights reserved. Materials Performance, November 2001
Electrical Grounding Case Histories
Copper Grounding Systems Have a Negative Effect on Cathodic Protection in Production Facilities
The Conflict Between Copper Grounding Systems and CP - NACE International. All rights reserved. Materials Performance, September 1999
The Buried Reference Electrode: A Critical Long Term Performance Study - NACE International. All rights reserved. Paper No. 673 reproduced with permission from CORROSION98 Annual Conference and Exhibition
Induced AC Voltages on Pipelines May Present a Serious Hazard - Pipeline and Gas Journal, October 1997
Basic Concepts of Induced AC Voltages on Pipelines - NACE International. All rights reserved. Materials Performance, July 1995
Factors That Can Affect CP Testing of Galvanic Systems For USTs
Cathodic Protection of Power Line Structure Foundations - NACE International. All rights reserved. Paper No. 227 reproduced with permission from CORROSION/88 Annual Conference and Exhibition, St. Louis, MO
Alternatives to Copper Grounding in Sites Requiring Cathodic Protection - NACE International. All rights reserved. Paper No. 341 reproduced with permission from CORROSION/86 Annual Conference and Exhibition, Houston, TX
Effects of Electrical Grounding on Corrosion - NACE International. All rights reserved. Paper No. 53 reproduced with permission from CORROSION/79 Annual Conference and Exhibition, Atlanta, GA
Canadian Storage Tank Market Witnesses Globalization of Standards

PowerPoint Presentations
PDF
The Facts & Myths About Shorted Casings - Direct Assessment Methodology Application - Corrosion Technology Week/2006 - 10 September 2006, Orlando, FL